Hydrogen Sulfide Sensor (H2S Sensor) - H2S-B1

? Range: 200ppm H2S limit of performance warranty
? Sensitivity: 300 to 450 nA/ppm in 20ppm H2S
? Response time t90: < 55 (s) from zero to 20ppm H2S
? Resolution: < 0.05 RMS noise (ppm equivalent)
? Temperature range : -30 to 50 ℃
? Pressure range: 80 to 12 kPa
? Humidity range: 15 to 90 % rh
? Weight: < 13g

  • Model Number: H2S-B1
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Hydrogen Sulfide Sensor (H2S Sensor)
  • Hydrogen Sulfide Sensor (H2S Sensor)
Mouse over image to zoom
Share:

Product Specification

H2S-B1 Hydrogen Sulfide Sensor (H2S Sensor) Description
Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.

H2S-B1 Hydrogen Sulfide Sensor sizes:
32mm diameter package, the best choice for fixed site applications

With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.

H2S-B1 Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE
Sensitivity
nA/ppm in 20ppm H2S
300 to 450
Response time
t90 (s) from zero to 20ppm H2S
< 55
Zero current
ppm equivalent in zero air
± 0.8
Resolution
RMS noise (ppm equivalent)
< 0.05
Range
ppm H2S limit of performance warranty
200
Linearity
ppm error at full scale, linear at zero and 20ppm H2S
1 to -5
Overgas limit
maximum ppm for stable response to gas pulse
500



H2S-B1 Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME
Zero drift
ppm equivalent change/year in lab air 
< 0.05
Sensitivity drift
% change/year in lab air, monthly test
< 3
Operating life
months until 80% original signal (24 month warranted)
> 24



H2S-B1 Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 20ppm
80 to 92
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 20ppm
100 to 110
Zero @ -20°C
ppm equivalent change from 20°C
< ± 0.5
Zero @ 50°C
ppm equivalent change from 20°C
< 0 to 1.5



H2S-B1 Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY
NO2   sensitivity
% measured gas @ 10ppm NO2
< -30
Cl2     sensitivity
% measured gas @ 10ppm Cl2
< -25
NO     sensitivity
% measured gas @ 50ppm NO
< 35
SO2   sensitivity
% measured gas @ 20ppm SO2
< 18
CO     sensitivity
% measured gas @ 400ppm CO
< 3
H2     sensitivity
% measured gas @ 400ppm H2
< 0.5
C2H4 sensitivity
% measured gas @ 400ppm C2H4
< 0.5
NH3   sensitivity 
% measured gas @ 400ppm NH3
< 0.1
CO2   sensitivity
% measured gas @ 5% CO2
< 0.1



H2S-B1 Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS
Temperature range
°C -30 to 50
Pressure range
kPa 
80 to 12
Humidity range
% rh
15 to 90
Storage period
months @ 3 to 20°C (stored in sealed pot)
6
Load resistor
Ω (recommended)
10 to 47
Weight
g
< 13

Matched Transmitter board for H2S-B1 H2S Sensor

4-20mA Analogue Transmitter Board
  ? Factory calibration, custom-set for immediate use
  ? Wide operating voltage range
  ? Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.


4-20 mA Digital Transmitter Board
   ? Factory calibration, custom-set for immediate use
   ? Digital zero, sensitivity and temperature compensation
   ? Digital and 4-20mA output
   ? Biased or unbiased operation
   ? Calibration and range change

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
a级亚洲片精品久久久久久久| 亚洲精品电影在线| WWW夜片内射视频日韩精品成人| 国内精品51视频在线观看| 精品剧情v国产在免费线观看| 久久亚洲精品中文字幕| 国产精品天干天干在线综合| 久久99精品久久久久久清纯| 亚洲国产精品不卡在线电影| 国产玖玖玖九九精品视频| 青春草国产成人精品久久 | 成人午夜精品网站在线观看| 国产精品色拉拉免费看| 亚洲av永久无码精品国产精品| www.久久精品| 精品亚洲成a人在线观看| 精品国产一二三产品价格| 久久精品国产精品亚洲艾| A级精品国产片在线观看| 日韩成人国产精品视频| 国产精品久久久久久搜索 | 国产精品1区2区| 亚洲AV日韩精品久久久久久久| 久久久久这里只有精品| 国产精品一区二区久久乐下载| 成人精品一区二区户外勾搭野战| 亚洲综合一区二区精品导航 | 91精品国产91| 亚洲精品视频久久| 久久免费观看国产精品| 国产69精品久久久久9999APGF| 人妻少妇精品久久| 国产精品模特hd在线| 蜜桃精品免费久久久久影院| 精品久久久久久蜜臂a∨| 91精品免费不卡在线观看| 久久亚洲国产精品| 亚洲国产精品va在线播放| 精品国产品香蕉在线观看75| 中文精品久久久久国产网站| 久久精品国产99久久香蕉|