Limiting Current Type Zirconia Oxygen Sensor - SO-A0-050

? TO39 Housing
? Measuring gas: Oxygen concentration
? Measuring medium: Gaseous atmosphere
? Measuring principle: Limiting current type sensor
? Measuring ranges: 0.05 - 5.0 vol.% O2
? Output current: 150 μA - 250 μA
? Accuracy: ±500 ppm O2
? Reproducibility: < 250 ppm O2

  • Model Number: SO-A0-050
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Limiting Current Type Zirconia Oxygen Sensor
  • Limiting Current Type Zirconia Oxygen Sensor
Mouse over image to zoom
Share:

Product Specification

SO-A0-050 Limiting Current Type Zirconia Oxygen Sensor Operational Principle
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.

SO-A0-050 TO39 Housing, ? 9.2 mm; H= 6.4 mm; pin distance 3.59 mm.

Below the advantages of the Zirconia Oxygen Sensor SO-A0-050:
? Measuring range 0.05 to 5 vol.% oxygen
High accuracy
For many types a more or less linear characteristic
Small temperature dependence of the sensor signal
Low interference with other gases
Long service life
In many cases "Single point calibration" necessary only once

SO-A0-050 Limiting Current Type Zirconia Oxygen Sensor Applications:
Medical
  ? Oxygen Concentrators
  ? Incubators
Laboratory
  ? Inert gas processing cabinets (Glove boxes)
  ? Incubators (controlled bacterial growth)
Food industry
  ? Packaging
  ? Controlled food testing
  ? Monitoring fruit ripening processes (storage / transport)
Household/Gastronomy
  ? High-temperature humidity measurements (> 100°C) for baking / roast automation
Measuring technique
  ? Oxygen Meters (stationary / portable)
  ? Measurements under controlled O2 content
  ? Air conditioning and ventilation 
Security technology/Monitoring
  ? Fire protection (increased N2 atmosphere e.g. Server rooms)
  ? Greenhouses, wine cellar
  ? Gas storage, refineries
  ? Diving
  ? Fermentation units
(Electrical-) industry
  ? Inert gas processing machines and cabinets
  ? Inert gas welding monitoring
  ? Storage with increased N2 atmosphere (oxidation prevention)
  ? Drying units
  ? Nitrogen concentrators
  ? Exhaust gas measurement

SO-A0-050 Limiting Current Type Zirconia Oxygen Sensor Characteristic Data:

Measuring gas
Oxygen concentration
Measuring medium
Gaseous atmosphere
Measuring principle
Limiting current type sensor
Measuring ranges
0.05 - 5.0 vol.% O2
Response time (t90)
2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber)
Sensor voltage / heating voltage / power consumption / heater cold resistance
   Sensor voltage:
   Heating voltage:
   Power consumption:
   Cold resistance:
0.7 to 1.6 Volt
3.6 to 4.4 Volts
1.3 to 1.8 Watts (depends on application and packaging)
R(25°C) = 3.25Ω ± 0.20Ω
Warm up time
Min. 30 s
Maximum permissible 
operating temperature

350°C (*)
*Depending on the cable and filter assembly (see paragraph: specification, Cable assembly)
Permissible volumetric flow 
rate (Purging the sensor)

For all sensor types, the maximum flow rate depends on the way of purging the sensor 
(sensor in direct gas flow, gas beam shape, etc.) and the size of the measuring chamber. 
Exception: SO-E1-xxx (TO8 + hose connection for direct gassing). Permissible flow 
[ml/min]: 100 - 500 (optimal: 250)

Lifetime (MTTF)
 ~ 20.000 hours (*)
*Depending on measuring medium. Stated lifetime refers to a heated, operated sensor of 
type SO-xx-250 and SO-xx-960. A failure or reaching the lifetime typically means a slight 
deviation from the dispatch specifications.

Vibration resistance
Sensors based on the TO8 socket as well as those built with a TO39 socket (SO-Bx-xxx, 
SO-Ex-xxx, SO-Ax-xxx) meet the European Norm EN60068-2-6 (Sinusoidal vibration tests).


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
国产成人精品无码一区二区三区 | 欧美成人aaa片一区国产精品| 亚洲国产成人久久精品99| 国产精品特级毛片一区二区三区| 国产精品∧v在线观看| 亚洲欧洲国产日韩精品| HEYZO无码综合国产精品| 亚洲精品国产国语| 久久久久久久久毛片精品 | 久久se精品一区精品二区国产| 亚洲精品欧美综合四区| 久久亚洲日韩精品一区二区三区| 亚洲精品WWW久久久久久| 国产精品亚洲av色欲三区| 2022国产精品手机在线观看| 久久久久久久久久久免费精品| 亚洲精品无码日韩国产不卡av| 日韩精品免费视频| 国产亚洲精品激情都市| 又紧又大又爽精品一区二区| 精品免费人成视频app| 久久9精品久久久| 日韩精品无码久久一区二区三| 国产香蕉一区二区精品视频| 久久国产三级精品| 中文字幕精品视频在线| 国产成人无码精品一区在线观看| 热久久精品免费视频| 国产91久久精品一区二区| 国产丝袜在线精品丝袜| 国产福利电影一区二区三区,亚洲国模精品一区 | 亚洲无码精品浪潮| 国产成人综合色视频精品| 亚洲日韩国产AV无码无码精品| 18精品久久久无码午夜福利| 亚洲AV乱码久久精品蜜桃| 国产午夜精品久久久久免费视| 久久99精品免费一区二区| 国产高清一级毛片精品| 日韩经典精品无码一区| 国产亚洲综合精品一区二区三区|