Limiting Current Type Zirconia Oxygen Sensor - SO-B0-050

? TO8 Housing
? Measuring gas: Oxygen concentration
? Measuring medium: Gaseous atmosphere
? Measuring principle: Limiting current type sensor
? Measuring ranges: 0.05 - 5.0 vol.% O2
? Output current: 150 μA - 250 μA
? Accuracy: ±500 ppm O2
? Reproducibility: < 250 ppm O2

  • Model Number: SO-B0-050
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Limiting Current Type Zirconia Oxygen Sensor
  • Limiting Current Type Zirconia Oxygen Sensor
Mouse over image to zoom
Share:

Product Specification

SO-B0-050?Limiting Current Type Zirconia Oxygen Sensor Operational Principle
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.

SO-B0-050 TO8 Housing, ? 15.3 mm; H= 13.7 mm; pin distance 7.18 mm

Below the advantages of the Zirconia Oxygen Sensor?SO-B0-050:
? Measuring range 0.05 to 5.0 vol.% oxygen
? High accuracy
? For many types a more or less linear characteristic
? Small temperature dependence of the sensor signal
? Low interference with other gases
? Long service life
? In many cases "Single point calibration" necessary only once

SO-B0-050?Limiting Current Type Zirconia Oxygen Sensor?Applications:
Medical
? ? Oxygen Concentrators
? ? Incubators
Laboratory
? ? Inert gas processing cabinets (Glove boxes)
? ? Incubators (controlled bacterial growth)
Food industry
? ? Packaging
? ? Controlled food testing
? ? Monitoring fruit ripening processes (storage / transport)
Household/Gastronomy
? ? High-temperature humidity measurements (> 100°C) for baking / roast automation
Measuring technique
? ? Oxygen Meters (stationary / portable)
? ? Measurements under controlled O2 content
? ? Air conditioning and ventilation?
Security technology/Monitoring
? ? Fire protection (increased N2 atmosphere e.g. Server rooms)
? ? Greenhouses, wine cellar
? ? Gas storage, refineries
? ? Diving
? ? Fermentation units
(Electrical-) industry
? ? Inert gas processing machines and cabinets
? ? Inert gas welding monitoring
? ? Storage with increased N2 atmosphere (oxidation prevention)
? ? Drying units
? ? Nitrogen concentrators
? ? Exhaust gas measurement


SO-B0-050?Limiting Current Type Zirconia Oxygen Sensor?
Characteristic Data:

Measuring gas
Oxygen concentration
Measuring medium
Gaseous atmosphere
Measuring principle
Limiting current type sensor
Measuring ranges
0.05 - 5.0 vol.% O2
Response time (t90)
2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber)
Sensor voltage / heating voltage / power consumption / heater cold resistance
? ?Sensor voltage:
? ?Heating voltage:
? ?Power consumption:
?? Cold resistance:
0.7 to 1.6 Volt
3.6 to 4.4 Volts
1.3 to 1.8 Watts (depends on application and packaging)
R(25°C) = 3.25Ω ± 0.20Ω
Warm up time
Min. 30 s
Maximum permissible?
operating temperature

350°C (*)
*Depending on the cable and filter assembly (see paragraph: specification, Cable assembly)
Permissible volumetric flow?
rate (Purging the sensor)

For all sensor types, the maximum flow rate depends on the way of purging the sensor?
(sensor in direct gas flow, gas beam shape, etc.) and the size of the measuring chamber.?
Exception: SO-E1-xxx (TO8 + hose connection for direct gassing). Permissible flow?
[ml/min]: 100 - 500 (optimal: 250)

Lifetime (MTTF)
?~ 20.000 hours (*)
*Depending on measuring medium. Stated lifetime refers to a heated, operated sensor of?
type SO-xx-250 and SO-xx-960. A failure or reaching the lifetime typically means a slight?
deviation from the dispatch specifications.

Vibration resistance
Sensors based on the TO8 socket as well as those built with a TO39 socket (SO-Bx-xxx,?
SO-Ex-xxx, SO-Ax-xxx) meet the European Norm EN60068-2-6 (Sinusoidal vibration tests).


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
国产亚洲福利精品一区| 日韩精品一二三四区| 无码精品A∨在线观看免费| 国产私拍福利精品视频推出 | 国产精品99久久不卡| 精品国产亚洲第一区二区三区| 精品久久久久久久免费人妻| 国产成人精品男人的天堂网站| 伊人久久精品影院| 精品国产AⅤ一区二区三区4区| 最新国产精品精品视频| 久久这里只精品国产免费10| 91精品国产三级在线观看| 久久6这里只有精品| 国产精品夜夜春夜夜爽久久小| 热99re久久精品2久久久| 国产91精品一区| 999成人精品视频在线| 久久99久久99精品| 95在线观看精品视频| 日本精品一区二区在线播放| xxxxbbbb国产精品| 国产区精品一区二区不卡中文| 精品综合久久久久久888蜜芽| 2021国产精品视频| 国产69久久精品成人看| 亚洲精品午夜无码专区| 亚洲精品高清视频| 国产精品爽黄69天堂a片| 亚洲第一区精品观看| 久久国产乱子免费精品| 亚洲乱码一区二区三区国产精品| 国产精品午夜高清在线观看| 老司机精品免费视频| 97精品伊人久久久大香线焦| 久热爱精品视频在线| 国产精品片在线观看手机版 | 9丨精品国产高清自在线看| 99热在线只有精品| 精品国产日韩亚洲一区91| 91精品最新国内在线播放|