Limiting Current Type Zirconia Oxygen Sensor - SO-E2-020

? TO8 Housing
? Measuring gas: Oxygen concentration
? Measuring medium: Gaseous atmosphere
? Measuring principle: Limiting current type sensor
? Measuring ranges: 0.01 - 2.0 vol.% O2
? Output current: 150 μA - 250 μA
? Accuracy: ±200 ppm O2
? Reproducibility: < 100 ppm O2

  • Model Number: SO-E2-020
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Limiting Current Type Zirconia Oxygen Sensor
  • Limiting Current Type Zirconia Oxygen Sensor
Mouse over image to zoom
Share:

Product Specification

SO-E2-020 Limiting Current Type Zirconia Oxygen Sensor Operational Principle
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.

SO-E2-020 TO8 Housing, ? 15.3 mm; H= 13.7 mm; pin distance 7.18 mm


Below the advantages of the Zirconia Oxygen Sensor SO-E2-020:
? Measuring range 0.01 to 2.0 vol.% oxygen
? High accuracy
? For many types a more or less linear characteristic
? Small temperature dependence of the sensor signal
? Low interference with other gases
? Long service life
? In many cases "Single point calibration" necessary only once


SO-E2-020 Limiting Current Type Zirconia Oxygen Sensor Applications:
Medical
  ? Oxygen Concentrators
  ? Incubators
Laboratory
  ? Inert gas processing cabinets (Glove boxes)
  ? Incubators (controlled bacterial growth)
Food industry
  ? Packaging
  ? Controlled food testing
  ? Monitoring fruit ripening processes (storage / transport)
Household/Gastronomy
  ? High-temperature humidity measurements (> 100°C) for baking / roast automation
Measuring technique
  ? Oxygen Meters (stationary / portable)
  ? Measurements under controlled O2 content
  ? Air conditioning and ventilation 
Security technology/Monitoring
  ? Fire protection (increased N2 atmosphere e.g. Server rooms)
  ? Greenhouses, wine cellar
  ? Gas storage, refineries
  ? Diving
  ? Fermentation units
(Electrical-) industry
  ? Inert gas processing machines and cabinets
  ? Inert gas welding monitoring
  ? Storage with increased N2 atmosphere (oxidation prevention)
  ? Drying units
  ? Nitrogen concentrators
  ? Exhaust gas measurement


SO-E2-020 Limiting Current Type Zirconia Oxygen Sensor 
Characteristic Data:

Measuring gas
Oxygen concentration
Measuring medium
Gaseous atmosphere
Measuring principle
Limiting current type sensor
Measuring ranges
0.01 - 2.0 vol.% O2
Response time (t90)
2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber)
Sensor voltage / heating voltage / power consumption / heater cold resistance
   Sensor voltage:
   Heating voltage:
   Power consumption:
   Cold resistance:
0.7 to 1.6 Volt
3.6 to 4.4 Volts
1.3 to 1.8 Watts (depends on application and packaging)
R(25°C) = 3.25Ω ± 0.20Ω
Warm up time
Min. 30 s
Maximum permissible 
operating temperature

350°C (*)
*Depending on the cable and filter assembly (see paragraph: specification, Cable assembly)
Permissible volumetric flow 
rate (Purging the sensor)

For all sensor types, the maximum flow rate depends on the way of purging the sensor 
(sensor in direct gas flow, gas beam shape, etc.) and the size of the measuring chamber. 
Exception: SO-E1-xxx (TO8 + hose connection for direct gassing). Permissible flow 
[ml/min]: 100 - 500 (optimal: 250)

Lifetime (MTTF)
 ~ 20.000 hours (*)
*Depending on measuring medium. Stated lifetime refers to a heated, operated sensor of 
type SO-xx-250 and SO-xx-960. A failure or reaching the lifetime typically means a slight 
deviation from the dispatch specifications.

Vibration resistance
Sensors based on the TO8 socket as well as those built with a TO39 socket (SO-Bx-xxx, 
SO-Ex-xxx, SO-Ax-xxx) meet the European Norm EN60068-2-6 (Sinusoidal vibration tests).


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
免费看一级毛片在线观看精品视频| 亚洲国产精品VA在线看黑人| 亚洲视频精品在线| 尤物在线观看精品国产福利片| 亚洲国产精品无码久久久不卡 | 久久99精品久久久久久水蜜桃| 成人精品一区二区三区不卡免费看| 人妻精品久久无码区| 久久国产精品亚洲一区二区| 亚洲国产精品不卡毛片a在线| 99在线精品免费视频九九视| 国内精品免费视频精选在线观看| 国产女精品视频在ktv| 日本阿v精品视频在线观看| 国产午夜精品一区二区三区漫画| 国产成人啪精品视频免费网| 亚洲一区精品视频在线| 精品一区二区久久| 国产免费久久精品丫丫| 精品国产自在现线久久| 99久久国产热无码精品免费| 亚洲AV日韩精品久久久久| 久久精品国产第一区二区| 在线观看亚洲精品专区| 国产精品亚洲精品观看不卡| 亚洲精品国产成人专区| 中文字幕在线精品视频入口一区 | 自拍偷自拍亚洲精品偷一| 91亚洲国产成人久久精品网址| 国产成人无码久久久精品一| 精品无码三级在线观看视频 | 国产热re99久久6国产精品| 精品久久久久久无码不卡| 久久国产精品无码一区二区三区| 国产原创精品视频| 99国产精品一区二区 | 久久亚洲国产午夜精品理论片| 九九热这里只有国产精品| 老湿机一区午夜精品免费福利| 精品久久久久久久久亚洲偷窥女厕| 国产成人精品高清在线观看99|