MIPEX Low-power NDIR Optical Gas Sensor CH4 Methane Sensor - MIPEX-04
Ultra-low power consumption – less than 35?μA average (~0.1?mW)
Optimized for IoT and portable detectors, including compact gas clips
Life time – over 10 years of operation
Enables gas analyzers to run on a single battery for over 2 years without recharging or maintenance.
- Quantity:
- - +
Product Specification
NDIR Sensor CH4 Methane Sensor MIPEX-04 Description:
MIPEX-04 CH? is an ultra-low power NDIR sensor for continuous methane detection in portable and wireless safety systems, including gas clip devices and battery-powered analyzers.
Its energy-efficient design enables autonomous operation without recharging or maintenance for up to 24 months.
The combination of low power consumption, certified explosion protection, and robust dual-wavelength optics makes MIPEX-04 a reliable choice for industrial gas detection in explosive atmospheres.
NDIR Sensor CH4 Methane Sensor?MIPEX-04?CH??ADVANTAGES:
- Ultra-low power consumption – less than 35?μA average (~0.1?mW)
- Optimized for IoT and portable detectors, including compact gas clips
- Life time – over 10 years of operation
- Enables gas analyzers to run on a single battery for over 2 years without recharging or maintenance.
NDIR Sensor CH4 Methane Sensor?MIPEX-04??Specifications:
|
Parameter |
Value |
|
General specification |
? |
|
Gas sampling method: |
Diffusion |
|
Operating principle: |
NDIR |
|
Calibration gas |
CH? |
|
Relative humidity |
up to 98% (without condensation) |
|
Atmospheric pressure, kPa |
80…120 |
|
Temperature, °C |
-40...+60 |
|
Warm-up time, sec |
≤ 120 |
|
Housing material |
Polycarbonate Lexan? |
|
Overall dimensions, mm |
52×24×18 |
|
Weight, g |
11.0…13.5 |
|
Measurement specification |
? |
|
Measurement range, % vol. |
0…2.5 |
|
Variability (+20…+25 ?C) |
± 0.1% vol. or ± 5% of readings (whichever is greater) |
|
Response time t(90), sec |
≤ 30 |
|
Electrical specification |
? |
|
Operating supply voltage, VDC |
+2.8…+5.0 |
|
Maximum supply voltage, VDC |
+5.5 |
|
Communication interface |
UART |
|
Average current, μA |
25…35 max at normal conditions |
|
Peak current, mA |
9 max |
|
Sensor is designed in compliance with: |
|
|
|
I M1 / II 1G Ex ia I Ma / Ex ia IIC Ga according to EN IEC 60079-0 / EN 60079-11 |
|
|
C I, Div1, Gr A,B,C,D; C I, Zone 0, AEx ia IIC Ga; Ex ia IIC Ga according to UL 913, CAN/CSA-C22.2 No.157-92 |
|
|
Ex ia I Ma/Ex ia IIC Ga according to IEC 60079-0, IEC 60079-11 |
If you cannot find what you want, you can entrust ISweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector