Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor) - CO/H2S-D2

? Range: 1000 ppm CO limit of performance warranty
? Range: 100 ppm H2S limit of performance warranty
? Sensitivity: 27 to 55 nA/ppm in 400ppm CO
? Sensitivity: 90 to 160 nA/ppm in 20ppm H2S
? Response time t90: < 25 (s) from zero to 400ppm CO
? Response time t90: < 30 (s) from zero to 20ppm H2S @ 20℃
? Temperature range?: -30 to 50?℃?
? Humidity range: 15 to 90 %rh continuous

  • Model Number: CO/H2S-D2
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor)
  • Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor)
Mouse over image to zoom
Share:

Product Specification

CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction
The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously.

Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide. 

Proven in the field over many years, these sensors perform well even under long term, challenging conditions.

D2 Specification Carbon Monoxide Channel

Carbon Monoxide Sensor PERFORMANCE
Sensitivity
nA/ppm in 400ppm CO
27 to 55
Response time
t90 (s) from zero to 400ppm CO
< 25
Zero current
ppm equivalent in zero air
< ± 6
Resolution
rms noise (ppm equivalent)
1
Range
ppm CO limit of performance warranty
1000
Linearity
ppm error at full scale, linear at zero and 400 ppm CO
< 40
Overgas limit
maximum CO for stable response to gas pulse
5000



Carbon Monoxide Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
< 0.5
Sensitivity drift
% change/year in lab air, monthly test
< 4
Operating life
months until 80% original signal (24 month warranted)
24



Carbon Monoxide Sensor ENVIRONMENTAL
Sensitivity @ -20℃
% (output @ -20/output @ 20) @ 100ppm CO
45 to 70
Sensitivity @ 50
 % (output @ 50/output @ 20) @ 100ppm CO
105 to 125
Zero @ -20
ppm equivalent change from 20
-1 to 1
Zero @ 50
ppm equivalent change from 20
-1 to 4



Carbon Monoxide Sensor CROSS SENSITIVITY

Filter Capacity
ppm-hours of Hydrogen Sulfide
15,000
H2S  sensitivity
% measured gas @ 20ppm H2S
< 8
NO2  sensitivity
% measured gas @ 10ppm NO2
< 0.1
Cl2    sensitivity
% measured gas @ 10ppm Cl2
< 0.1
NO    sensitivity
% measured gas @ 50ppm NO
< 50
SO2   sensitivity
% measured gas @ 20ppm SO
< 0.1
H2     sensitivity
% measured gas @ 400ppm H2 @ 20
< 55
C2H4 sensitivity
% measured gas @ 400ppm C2H4
< 200
NH3   sensitivity
% measured gas @ 20ppm NH3
< 0.1



Carbon Monoxide Sensor KEY SPECIFICATIONS
Temperature range

-30 to 50
Pressure range
kPa 
80 to 120
Humidity range
%rh continuous (see note below)
15 to 90
Storage period
months @ 3 to 20 (stored in sealed pot)
6
Load resistor
Ω (recommended)
10 to 47
Weight
g
< 2


D2 Specification Hydrogen Sulfide Channel

Hydrogen Sulfide Sensor PERFORMANCE
Sensitivity
nA/ppm in 20ppm H2S
90 to 160
Response time
t90 (s) from zero to 20ppm H2S @ 20
< 30
Zero current
ppm equivalent in zero air 
< ± 1
Resolution
rms noise (ppm equivalent)
<0.25
Range
ppm  H2S limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero and 20ppm H2S
0 to -9
Overgas limit
maximum ppm H2S  for stable response to gas pulse
400



Hydrogen Sulfide Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
< 0.1
Sensitivity drift
% change/year in lab air, monthly test
< 2
Operating life
months until 80% original signal (24 month warranted)
24



Hydrogen Sulfide Sensor ENVIRONMENTAL
Sensitivity @ -20
% (output @ -20/output @ 20) @ 20ppm H2S
75 to 90
Sensitivity @ 50
% (output @ 50/output @ 20) @ 20ppm H2S
103 to 112
Zero @ -20
ppm equivalent change from 20
-0.3 to 0.2
Zero @ 50
ppm equivalent change from 20
< ±1



Hydrogen Sulfide Sensor CROSS SENSITIVITY
NO2 sensitivity
% measured gas @ 10ppm NO2
< -10
Cl2    sensitivity
% measured gas @ 10ppm Cl2
< -10
NO    sensitivity
% measured gas @ 50ppm NO
< 10
SO2  sensitivity
% measured gas @ 20ppm SO2
< 10
CO    sensitivity
% measured gas @400ppm CO
< 2
H2     sensitivity
% measured gas @400ppm H2
< 1
C2H4 sensitivity
% measured gas @400ppm C2H4
<1
NH3   sensitivity
% measured gas @ 20ppm NH3
0


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
中日韩产精品1卡二卡三卡| 亚洲午夜精品在线| 久久久精品久久久久久96| 日韩A∨精品日韩在线观看 | 韩国精品一区视频在线播放| 久久国产精品-国产精品| 国产精品青草久久| 亚洲精品人成电影网| 在线中文字幕精品第5页| 国产精品社区在线观看| 精品亚洲AV无码一区二区三区| 亚洲精品二区国产综合野狼| 国产精品久久久小说| 91热成人精品国产免费| 久久国产精品-久久精品| 一区二区三区四区精品| 一区国产传媒国产精品| 日韩精品久久久肉伦网站| 91精品国产综合久久精品| 国产亚洲Av综合人人澡精品| 亚洲欧美国产精品专区久久| 久久91亚洲精品中文字幕| 精品国产呦系列在线观看免费 | 国产精品久久久久久久久电影网| 精品久久久久久无码专区不卡| 日本精品久久久中文字幕| 2022年国产精品久久久久| 国产精品资源一区二区| 91精品国产91| 在线精品91青草国产在线观看| 国产精品成人观看视频国产奇米| 精品国产午夜福利在线观看| 免费国产在线精品一区| 欧洲精品免费一区二区三区| 久久精品国产99久久久| 日日夜夜精品视频| 国产精品91在线| 精品一区精品二区制服| 91精品国产自产在线观看永久∴ | 国产精品hd免费观看| 国产亚洲精品美女|