Hydrogen Sensor - 4H2-1000
Temperature Range:-20 oC to 50 oC
Operating Humidity:15 to 90%RH non-condensing
Pressure Range:90 to 110 kPa
Bias Potential:0 mV
- Quantity:
- - +
Product Specification
Performance Characteristics:
|
Part Number |
CLE-0613-400 |
|
Nominal Range |
0 to 1000 ppm |
|
Maximum Overload |
2000 ppm |
|
Sensitivity |
0.02±0.01μA/ppm |
|
Baseline(20 ℃) |
<±0.2 μA |
|
Baseline Drift(-20 to 50 ℃) |
0 to 10 ppm equivalent |
|
Resolution |
10 ppm |
|
Response Time(T90) |
≤70 seconds |
|
Linearity |
Linear |
|
Long Term Output Drift |
< 2% signal/month |
Operation Conditions:
|
Temperature Range |
-20 ℃ to 50 ℃ |
|
Operating Humidity |
15 to 90 %RH non-condensing |
|
Pressure Range |
90 to 110 kPa |
|
Bias Potential |
0 mV |
|
Storage Life |
6 months in sealed container |
|
Storage Temperature |
0 ℃ to 20 ℃ |
|
Expected Operating Life |
2 years in air |
|
Warranty |
12 months from date of despatch |
Physical Characteristics:
|
Weight |
5 g (approx) |
|
Orientation Sensitivity |
None |