Limiting Current Type Zirconia Oxygen Sensor - SO-E2-960

? TO8 Housing
? Measuring gas: Oxygen concentration
? Measuring medium: Gaseous atmosphere
? Measuring principle: Limiting current type sensor
? Measuring ranges: 1.00 - 96.0 vol.% O2?
? Output current: 15 μA - 30 μA
? Accuracy: ±1.00 % O2
? Reproducibility: < 0.2 % O2

  • Model Number: SO-E2-960
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Limiting Current Type Zirconia Oxygen Sensor
  • Limiting Current Type Zirconia Oxygen Sensor
Mouse over image to zoom
Share:

Product Specification

SO-E2-960 Limiting Current Type Zirconia Oxygen Sensor Operational Principle
When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration.

SO-E2-960 TO8 Housing, ? 15.3 mm; H= 13.7 mm; pin distance 7.18 mm


Below the advantages of the Zirconia Oxygen Sensor SO-E2-960:
? Measuring range 1.00 to 96.0 vol.% oxygen
? High accuracy
? For many types a more or less linear characteristic
? Small temperature dependence of the sensor signal
? Low interference with other gases
? Long service life
? In many cases "Single point calibration" necessary only once


SO-E2-960 Limiting Current Type Zirconia Oxygen Sensors Applications:
Medical
  ? Oxygen Concentrators
  ? Incubators
Laboratory
  ? Inert gas processing cabinets (Glove boxes)
  ? Incubators (controlled bacterial growth)
Food industry
  ? Packaging
  ? Controlled food testing
  ? Monitoring fruit ripening processes (storage / transport)
Household/Gastronomy
  ? High-temperature humidity measurements (> 100°C) for baking / roast automation
Measuring technique
  ? Oxygen Meters (stationary / portable)
  ? Measurements under controlled O2 content
  ? Air conditioning and ventilation 
Security technology/Monitoring
  ? Fire protection (increased N2 atmosphere e.g. Server rooms)
  ? Greenhouses, wine cellar
  ? Gas storage, refineries
  ? Diving
  ? Fermentation units
(Electrical-) industry
  ? Inert gas processing machines and cabinets
  ? Inert gas welding monitoring
  ? Storage with increased N2 atmosphere (oxidation prevention)
  ? Drying units
  ? Nitrogen concentrators
  ? Exhaust gas measurement


SO-E2-960 Limiting Current TypeZirconia Oxygen Sensors Characteristic Data:

Measuring gas
Oxygen concentration
Measuring medium
Gaseous atmosphere
Measuring principle
Limiting current type sensor
Measuring ranges
1.00 - 96.0 vol.% O2
Response time (t90)
2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber)
Sensor voltage / heating voltage / power consumption / heater cold resistance
   Sensor voltage:
   Heating voltage:
   Power consumption:
   Cold resistance:
0.7 to 1.6 Volt
3.6 to 4.4 Volts
1.3 to 1.8 Watts (depends on application and packaging)
R(25°C) = 3.25Ω ± 0.20Ω
Warm up time
Min. 30 s
Maximum permissible 
operating temperature
350°C (*)
*Depending on the cable and filter assembly (see paragraph: specification, Cable assembly)
Permissible volumetric flow 
rate (Purging the sensor)
For all sensor types, the maximum flow rate depends on the way of purging the sensor 
(sensor in direct gas flow, gas beam shape, etc.) and the size of the measuring chamber. 
Exception: SO-E1-xxx (TO8 + hose connection for direct gassing). Permissible flow 
[ml/min]: 100 - 500 (optimal: 250)
Lifetime (MTTF)
 ~ 20.000 hours (*)
*Depending on measuring medium. Stated lifetime refers to a heated, operated sensor of 
type SO-xx-250 and SO-xx-960. A failure or reaching the lifetime typically means a slight 
deviation from the dispatch specifications.
Vibration resistance
Sensors based on the TO8 socket as well as those built with a TO39 socket (SO-Bx-xxx, 
SO-Ex-xxx, SO-Ax-xxx) meet the European Norm EN60068-2-6 (Sinusoidal vibration tests).


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
97久久精品午夜一区二区| 亚洲国产精品一区二区第一页免| 久久亚洲精品人成综合网| 久久亚洲国产成人精品无码区| 国产精品美女自在线观看免费| 中文字幕无码精品亚洲资源网久久| 98精品全国免费观看视频| 久久九九精品国产综合喷水| 在线精品亚洲一区二区小说| 2022年国产精品久久久久| 无码精品人妻一区二区三区影院| 国产精品任我爽爆在线播放 | 久久国产精品成人片免费| 国产精品无圣光一区二区| 国产亚洲午夜高清国产拍精品 | 78成人精品电影在线播放日韩精品电影一区亚洲 | 3d动漫精品啪啪一区二区中| 精品三级在线观看| 久久99精品国产一区二区三区| 国产在线精品二区| 孩交VIDEOS精品乱子| 成人精品视频一区二区三区| 精品国产国产综合精品| 精品国产毛片一区二区无码| 国产成人精品曰本亚洲79ren| 国产观看精品一区二区三区| 精品国产成人国产在线观看| 97久久精品午夜一区二区| 亚洲码国产精品高潮在线| 久久99国产精品久久99| 无码人妻精品一区二区在线视频| 久久精品国产精品亚洲色婷婷| 久久久久亚洲精品美女| 久久亚洲国产精品成人AV秋霞 | 精品亚洲AV无码一区二区 | 97久久超碰国产精品旧版 | 久久这里只有精品久久| 久久九九久精品国产日韩经典| 99re热久久精品这里都是精品| 亚洲国产精品美女| 亚洲av永久无码精品网址|