Remote Particle Counter - P235
? Measures 0.5 μm and 5.0 μm
? 0.1 CFM (2.83 LPM) flow rate
? Measures 2 channels of simultaneous data
? Power: 9-30 VDC
? Long life laser diode
? Concentration limit of 2,000,000 per ft3
? Operating Temperature: 5 to 35°C
? Operating Humidity: 20% to 95%RH non-condensing
- Quantity:
- - +
Product Specification
Remote Particle Counter
Model P235
The P235 remote particle counter measures 0.5 μm and 5.0 μm with a flow rate of 0.1 CFM (2.83 LPM). Integration is easy into a real-time monitoring or building management system via Modbus? RTU or Modbus? ASCII. The P235 is the smallest remote particle counter in the market and has easy mounting options. The P235 complies with ISO 21501-4 and includes a 2 year limited warranty.
P235 Remote Particle Counter Features & Benefits
? Measures 0.5 μm and 5.0 μm
? 0.1 CFM (2.83 LPM) flow rate
? Measures 2 channels of simultaneous data
? Long life laser diode
? Modbus? RTU or Modbus? ASCII outputs
? Concentration limit of 2,000,000 per ft3
? Complies with ISO 21501-4 and JIS B9921 standards
? Lightweight stainless steel enclosure
? Easy to clean and wipe down
? 2 year limited warranty
P235 Remote Particle Counter Specifications
Channel Sizes | 0.5 μm and 5.0 μm |
Counting Efficiency | 50% at 0.5 μm; 100% for particles > 0.75 μm (per JIS) |
Concentration Limits | 2,000,000 particles / ft3 at 5% coincidence loss |
Light Source | Long life laser diode |
Zero Count Level | <1 count / 5 minutes (per JIS B9921) |
Flow Rate | 0.1 CFM (2.83 LPM) |
Flow Control | Critical orifice |
Vacuum Requirements | External vacuum >15" (38.1 cm) of Hg |
Calibration | NIST traceable |
Sample Probe/Tubing | Isokinetic sampling probe |
Communication Interface | Modbus? RTU or ASCII outputs (specified upon order) |
Power | 9-30 VDC |
Dimensions (L x W x H) | 1.8" x 3.7" x 1.5" (4.5 cm x 9.3 cm x 3.8 cm) does not include probes |
Weight | 0.62 lb (0.28 kg) |
Standards | ISO 21501-4 and JIS B9921 |
Warranty | 2 year limited warranty |
Operating Conditions | 5 to 35°C, 20% to 95%RH non-condensing |
Storage Conditions | -20 to 50°C, Up to 98%RH non-condensing |
Optional Accessories | Isokinetic sampling probe, purge filter, data cable, vacuum and sample tubing |
If you cannot find what you want, you can entrust ISweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
4-channel Remote Particle Counter
-
Remote Particle Counter
-
Remote Particle Counter
-
Remote Airborne Particle Counter 0.3 μm @ 0.1 CFM
-
Remote Airborne Particle Counter 0.5 μm @ 0.1 CFM
-
Remote Particle Counter 0.3 μm @ 0.1 CFM
-
Remote Particle Counter 0.5 μm @ 0.1 CFM
-
Handheld Particle Counter 0.3 μm @ 0.1 CFM
-
Handheld Particle Counter 0.3 μm @ 0.1 CFM
-
Handheld Particle Counter 0.5 μm @ 0.1 CFM