Probe Style Relative Humidity Sensor Module - HM1500LF
? Small size product
? Product free from Lead, Cr(6+), Cd and Hg
? Humidity calibrated within +/-2% @55%RH
? Typical 1 to 3.6 Volts DC output for 0 to 100 % RH at 5 V DC supply
? Ratiometric to voltage supply from 4.75Vdc to 5Vdc.
? Patented solid polymer structure
? Full interchangeabilityr
- Quantity:
- - +
Product Specification
HM1500LF?Probe Style Relative Humidity Sensor?Module?FEATURES?
? Small size product
? Product free from Lead, Cr(6+), Cd and Hg
? Humidity calibrated within +/-2% @55%RH
? Typical 1 to 3.6 Volts DC output for 0 to 100 % RH at 5 V DC supply
? Ratiometric to voltage supply from 4.75Vdc to 5Vdc.
? Patented solid polymer structure?
? Full interchangeability
? High reliability and long term stability
? Not affected by water immersion
? Very low temperature dependence
? Suitable for 3 to 10 Vdc supply voltage
??Instantaneous de-saturation after long periods in saturation phase.
??Fast response time.
??Part could be washed with distilled water.
HM1500LF?Probe Style Relative Humidity Sensor?Module?APPLICATIONS
? Industrial
? Process control
? …?
HM1500LF?Probe Style Relative Humidity Sensor?Module?PERFORMANCE SPECS
MAXIMUM RATINGS
Ratings |
Symbol |
Value |
Unit |
Storage Temperature |
Tstg |
-30 to 70 |
°C |
Storage Humidity |
RHstg |
0 to 100 |
% RH |
Supply Voltage (Peak) |
Vs |
10 |
Vdc |
Humidity Operating Range |
RH |
0 to 100 |
% RH |
Temperature Operating Range |
Ta |
-40 to 60 |
°C |
ELECTRICAL CHARACTERISTICS
(Ta=23°C, Vs=5Vdc +/-5%, RL>1M? unless otherwise stated)?
Humidity Characteristics |
Symbol |
Min |
Typ |
Max |
Unit |
Humidity Measuring Range |
RH |
0 |
? |
100 |
%RH |
Relative Humidity Accuracy (10 to 95% RH) |
RH |
? |
+/-3 |
+/-5 |
%RH |
Supply Voltage (regulated at 5Vdc*) |
Vs |
? |
5 |
? |
Vdc |
Nominal Output @55%RH (at 5Vdc) |
Vout |
2.42 |
2.48 |
2.54 |
V |
Current consumption |
Ic |
? |
1.4 |
2 |
mA |
Temperature Coefficient (10 to 50°C) |
Tcc |
? |
- 0.05 |
-0.1 |
%RH/°C |
Average Sensitivity from 33% to 75%RH |
ΔVout/ΔRH |
? |
+26 |
? |
mV/%RH |
Sink Current Capability (RL=33k?) |
Is |
? |
? |
150 |
μA |
Humidity Hysteresis |
|
? |
|
?+/-1 |
%RH |
Time Constant (at 63% of signal,?static) 33% to 75%RH |
τ |
|
|
10 |
s |
Warm up time (electronic) |
tw |
? |
150 |
|
ms |
Humidity resolution |
? |
? |
0.4 |
? |
%RH |
Output Impedance |
Z |
? |
70 |
? |
? |
*Maximum power supply ramp up time to Vcc should be less than 4ms.
If you cannot find what you want, you can entrust ISweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Miniature Digital Relative Humidity and Temperature Sensor
-
Capacitive Humidity Sensor
-
Voltage Output Temperature and Humidity Sensor
-
Humidity and Temperature Sensor Module
-
Voltage Output Humidity and Temperature Sensor Module
-
Voltage Output Temperature and Humidity Sensor
-
Temperature Humidity Sensor Module
-
Frequency Output Temperature and Humidity Sensor
-
Capacitive Temperature and Humidity Sensor
-
Capacitive Temperature and Humidity Sensor