Mass Flowmeter for Gases - 41433

? Fast and accurate
? Low pressure drop
? Gas Calibration: Air, O2, N2, N2O
? Inlet/Outlet Diameter: 0.375” (9.53 mm)
? Flow Measurement Range: 0.01-20 Std L/min
? Volume Measurement Range: 0.01 - 99.9 liters?
? Pressure Measurement? Range?: 50-199 kPa absolute?
? Temperature Measurement? Range?: 0-50°C?
? ?DC Power Input?: 7.5 VDC ±1.5 V, 300 mA max?

  • Model Number: 41433
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Mass Flowmeter for Gases
  • Mass Flowmeter for Gases
  • Mass Flowmeter for Gases
Mouse over image to zoom
Share:

Product Specification

41433 Mass Flowmeter PRODUCT DETAILS
The TSI Nitrous Oxide Mass Flowmeter 41433 (LCD, 0.01-20L/min N2O, Air, O2, N2 3/8" tube) can be used for a multitude of gas flow measurement applications. Whether measuring gas flows in a laboratory or manufacturing setting, TSI general purpose mass flowmeters provide accurate results with multiple data output options. The display versions come complete with accessories making setup and operation fast and convenient. The TSI Nitrous Oxide Flowmeters are specified as three percent of flow rate reading. One TSI Nitrous Oxide Flowmeter covers the same range as three percent (or more) of full scale devices, with better accuracy at most points.

Four millisecond response ensures accuracy in fluctuating flows. This fast response time of the TSI mass flowmeter is ideal for closed-loop control systems and integrated volume measurements. Low pressure drop of the TSI Nitrous Oxide Flowmeter minimizes flow circuit back pressure and its impact on the system.

41433 Mass Flowmeter FEATURES AND BENEFITS
? Fast and accurate 
? Low pressure drop 

41433 Mass Flowmeter APPLICATIONS
? Medical 
? Industrial  
? Laboratory

41433 Mass Flowmeter SPECIFICATIONS – DIGITAL DISPLAY MODELS

Model
41433
Gas Calibration
Air, O2, N2, N2O
Inlet/Outlet Diameter
0.375” (9.53 mm)
Flow Measurement
Range
0.01-20 Std L/min
Accuracy — Air and O2
±2% of reading or 0.005 Std L/min, whichever is greater
Accuracy — N2
±3% of reading or 0.010 Std L/min, whichever is greater
Accuracy — Air and O2 mixture
N/A
Accuracy — N2O
±3% of reading or 0.010 Std L/min, whichever is greater
Response
4 ms to 63% of full scale flow
LCD Display Units
L/min, Std L/min, cm 3 /min, Std cm 3 /min
Overall Dimensions
5” x 2” x 1.25” (127 mm x 49 mm x 32 mm)
Volume Measurement
Range
0.01 - 99.9 liters
Accuracy
±2% of reading (see Operator’s Manual for additional details) 
Pressure Measurement
Range
50-199 kPa absolute
Accuracy
±1 kPa
Response
<4 ms to 63% of final value for step charge
Temperature Measurement
Range
0-50°C
Accuracy
±1°C at flow greater than 1 Std L/min
Response
<75 ms to 63% of final value for step change
Outputs
Analog
0-10 VDC flow only, zero and span adjustable via RS232
Digital
RS232
DC Power Input
7.5 VDC ±1.5 V, 300 mA max

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
CHINESE中国精品自拍| 国产福利微拍精品一区二区| 午夜精品久久久久蜜桃| 国产乱人伦偷精品视频不卡| 无码国产精品一区二区免费虚拟VR| 2021国产精品自拍| 国内精品久久久久久无码不卡| 精品性影院一区二区三区内射 | 国产精品VA在线观看无码不卡| 亚洲精品无码人妻无码| 国产精品理论片在线观看| 四虎国产精品免费久久| 亚洲国产精品自在线一区二区 | 51精品视频免费国产专区| 久久精品九九热无码免贵| 国产在线精品二区| 一区二区国产精品| 欧洲成人午夜精品无码区久久| 国产日产欧产精品精品蜜芽| 亚洲无删减国产精品一区| 国内精品久久久久久久久| 91精品国产一区二区三区左线| 久久精品国产精油按摩| 91麻豆精品国产片在线观看| 国产成人精品久久二区二区| 精品国产福利第一区二区三区| 国产精品亚洲片在线va| 青娱乐精品视频在线观看| 日韩精品视频在线观看免费| 久久精品视频观看| 四虎国产精品成人| 91精品国产91久久久久久蜜臀| 国产精品三级在线观看无码| 国产三级精品三级在线观看专1| 精品国产成a人在线观看| 亚洲AV无码精品色午夜果冻不卡 | 国产精品久久久久…| 国产成人麻豆亚洲综合无码精品| 亚洲国产日韩精品| 国产成人综合久久精品尤物| 99久久精品国产高清一区二区|