14-bit Digital Output Pressure Sensor - MEAS 86BSD

? Pressure?(bar): 0.07, 0.35, 1, 2, 5, 7, 10, 14, 20
? Pressure?(psi): 1, 2, 5, 15, 30, 50, 100, 150, 200, 300
? ±0.25% Accuracy
? ±1.0 Total Error Band
? I2C or SPI Interface protocols
? Compensated Temperature (≤5psi): 0~50°C
? Compensated Temperature (≥15psi): -20~ +80°C

  • Model Number: MEAS 86BSD
  • Data Sheet: Date Sheet File
Quantity:
- +
  • 14-bit Digital Output Pressure Sensor
  • 14-bit Digital Output Pressure Sensor
Mouse over image to zoom
Share:

Product Specification

86BSD Digital Output Pressure Sensor Specifications
? Stainless steel with O-ring seal
? Pressure/temperature read-out
? Digital output
? ASIC calibrated
? Absolute, gage
? Cable/connector option
? Low power option
? 16mm diaphragm diameter

The 86BSD is a small profile, media compatible, piezoresistive silicon pressure sensor packaged in a 316L stainless steel housing. This 14-bit digital output pressure sensor supports I2C and SPI interface protocols, may come in a 3.3 or 5.0Vdc supply voltage and is designed for o-ring mounting. The sensing package utilizes silicone oil to transfer pressure from the 316L stainless steel diaphragm to the sensing element.

The 86BSD is designed for high performance, low pressure applications. A custom ASIC is used for temperature compensation, offset correction, and provides a digital output of 10~90% or 5~95%.

For a similar sensor with stainless steel fittings, refer to the 85BSD digital output pressure sensor.

86BSD Digital Output Pressure Sensor Features
? Mountable with O-ring seal
? ±0.25% Accuracy
? ±1.0 Total Error Band
? Cable/connector option
? Low power option
? I2C or SPI Interface protocols

86BSD Digital Output Pressure Sensor Applications
? Level controls
? Tank level measurement
? Corrosive fluids and gas measurement systems
? Sealed systems
? Manifold pressure measurement
? Barometric pressure measurement
? Submersible depth monitoring

86BSD Digital Output Pressure Sensor Performance Specifications
Supply Voltage: 3.3Vdc
Ambient Temperature: 25°C (unless otherwise specified

Parameters
Min
Typ
Max
Units
Notes
Zero Pressure Output (10% ~ 90%)

666
Count Hex
1
Zero Pressure Output (5% ~ 95%)

333
Count Hex
1
Full Scale Pressure Output (10% ~ 90%)

399A
Count Hex
1
Full Scale Pressure Output (5% ~ 95%)

3CCB
Count Hex
1
Accuracy
-0.25
0.25 %Span
2
Total Error Band
-1
1 %Span
3
Pressure Resolution
0.008

%Span

Temperature Accuracy
-1.5
1.5 °C
4
Resolution – Temperature

0.1
°C

Input Voltage Range
2.7 3.3 5.5 V
1
Supply Current

3
mA

Insulation Resistance (50Vdc)
50

M?
5
Overpressure


2X Rated
6
Burst Pressure


3X Rated
7
Load Resistance (RL)
10

K?

Long Term Stability (Offset & Span)

±0.5

%Span/Year

Compensated Temperature (≤5psi)
0
50 °C

Compensated Temperature (≥15psi)
-20
+80 °C

Operating Temperature
-40
+125 °C

Storage Temperature
-40
+125 °C
8
Output Pressure Resolution


14 Bits

Output Temperature Resolution
8
11 Bits

Start Time to Data Ready


8.4 ms
9
Output Type
10% to 90% or 5% to 95%
Interface Type
I2C (ADDR, 0x28H)
I2C (ADDR, 0X36H)
I2C (ADDR, 0x46H)
SPI
Media – Pressure
Liquids and gases compatible with 316/316L Stainless Steel
Notes
1.  Measured at vacuum for absolute(A), ambient for gage(G) and sealed gage(S). Output is not ratiometric to supply voltage.
2.  Accuracy: combined linearity, hysteresis and repeatability.
3.  Total Error Band: includes calibration errors and temperature effects over the compensated range. See Figure 3.
4.  The deviation from a best fit straight line (BFSL) fitted to the output measured over the compensated temperature range. For errors beyond the compensated temperature range, See Figure 2.
5.  Between case and sensing element.
6.  2X or 400psi, whichever is less. The maximum pressure that can be applied to a transducer without changing the transducer's performance or accuracy.
7.  3X or 600psi, whichever is less. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
8.  Maximum temperature range for product with standard cable and connector is -20°C to +105°C.
9.  Start time to data ready is the time to get valid data after POR (Power on Reset). The time to get subsequent valid data is then specified by the response time specification.

86BSD Digital Output Pressure Sensor Ordering Information


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service
国产在视频线精品视频| 久久久亚洲精品视频| 国产精品嫩草影院一二三区入口 | 久久99精品久久久久久不卡| 亚洲国产成人91精品| 国产精品第一页在线| 91麻豆精品在线观看| 精品无码一级毛片免费视频观看| 国产成人精品久久免费动漫| 亚洲伊人久久精品影院| 视频久re精品在线观看| 99久久久国产精品免费牛牛| 精品无码人妻一区二区三区不卡| 亚洲av无码成人精品国产| 久久亚洲精品中文字幕无码| 国产精品激情综合久久| 精品无人区麻豆乱码无限制| 国产成人精品电影在线观看| 国产亚洲Av综合人人澡精品| 国产精品亚洲四区在线观看| 久久这里只精品热免费99| 国产精品一级AV在线播放| 十八禁无遮挡99精品国产| 日韩人妻精品无码一区二区三区| 精品国产青草久久久久福利| 国产精品青青青高清在线| 热久久视久久精品18| 亚洲国产精品无码久久久不卡| 亚洲国产成人精品91久久久| 亚洲精品蜜夜内射| 91精品一区二区| 久久久久久国产精品免费免费男同 | 精品400部自拍视频在线播放| 88aa四虎影成人精品| 久久精品aⅴ无码中文字字幕| 久久精品国产一区二区| 九九精品国产99精品| 国产免费久久精品| 国产精品jizz观看| 蜜臀91精品国产高清在线观看| 久久精品无码专区免费东京热|